Purposes£º
And compensation for thermocouple compensation wire cable for electric power, metallurgy, petroleum, chemical, textile and other industrial and national defense, scientific research and other departments Thermometer automated single point or multi-point connection¡£
Product standards£º
Thermocouple compensation wire£º GB/T4989-94
Use of property£º
Temperature: Heat level: -65 ¡æ ~ +200 ¡æ and -65 ¡æ ~ +260 ¡æ two£»
General level: -40 ¡æ ~ +70 ¡æ and -40 ¡æ ~ +105 ¡æ two£»
Minimum bend radius: compensation conductor: conductor diameter not less than 8 times£»
Compensation cable: There are no less than when the armored cable diameter 12 times, without armor when the cable diameter is not less than 6 times
The main technical indicators£º
Model, color alloy wire and insulation materials
Model |
Thermocouple
Dividing number |
Equipped with a thermocouple |
Compensation wire alloy wire |
Insulating layer of coloring |
Positive |
Negative |
Positive |
Negative |
BC |
B |
Platinum Rhodium 30 - Platinum Rhodium 6 |
Copper |
Copper |
|
Gray |
SC |
S |
Platinum Rhodium 10 - Platinum |
SPC( Copper ) |
SNC( Copper Nickel 0.6) |
Red |
Green |
RC |
R |
Platinum Rhodium 13 - Platinum |
RPC( Copper ) |
RNC( Copper Nickel 0.6) |
Red |
Green |
KCA |
K |
Ni-Cr - Ni Si |
KPCA( Iron ) |
KNCA( CopperNickel 2) |
Red |
Lan |
KCB |
KPCB( Copper ) |
KNCB( CopperNickel 4) |
Red |
Lan |
KX |
KPX( Nickel chrome 10) |
KNX( Ni Si 3) |
Red |
Black |
NC |
N |
Nickel chrome - Ni Si |
NPC( Iron ) |
NNC( CopperNickel 18) |
Red |
Gray |
NX |
NPX( Nickel chrome 14 Silicon ) |
NNX( Ni Si 4) |
Red |
Gray |
EX |
E |
Ni Si - Ni Si |
EPX( Nickel chrome 10) |
ENX( CopperNickel 45) |
Red |
Brown |
JX |
J |
Iron - CopperNickel |
JPX( Iron ) |
JNX( CopperNickel 45) |
Red |
Purple |
TX |
T |
Copper - CopperNickel |
TPX( Copper ) |
TNX( CopperNickel 45) |
Red |
White |
WC3/25 |
WRe3-WRe25 |
Tungsten - Tungsten rhenium 25 |
WPC3/25 |
WNC3/25 |
Red |
Yellow |
WC5/26 |
WRe5-WRe26 |
Tungsten - Tungsten rhenium 26 |
WPC5/26 |
WNC5/26 |
Red |
Orange |
Using color classification and protection layer
Use classification |
Accuracy and signs |
Sheath color |
General level |
Precision |
General level |
Precision |
General use |
G |
/ |
S |
Black |
Gray |
Heat use |
H |
/ |
S |
Black |
Yellow |
Tolerance and reciprocating resistance
Compensation wireModel |
Reciprocating resistance at 20 ¡æ ¦¸ / m is not greater than |
0.2mm2 |
0.5mm2 |
1.0mm2 |
1.5mm2 |
2.5mm2 |
NC or BC |
0.25 |
0.10 |
0.05 |
0.03 |
0.02 |
KCA |
3.50 |
1.40 |
0.70 |
0.47 |
0.28 |
KCB |
2.60 |
1.40 |
0.70 |
0.47 |
0.28 |
KX |
5.50 |
2.20 |
1.10 |
0.73 |
0.44 |
EX |
6.25 |
2.50 |
1.10 |
0.73 |
0.44 |
JX |
6.25 |
2.50 |
1.25 |
0.83 |
0.50 |
TX |
3.25 |
1.30 |
0.65 |
0.43 |
0.26 |
NC |
3.75 |
1.50 |
0.75 |
0.50 |
0.30 |
N |
7.15 |
2.86 |
1.43 |
0.95 |
0.57 |
WC3/25 |
0.50 |
0.20 |
0.10 |
0.07 |
0.04 |
WC5/26 |
0.50 |
0.20 |
0.10 |
0.07 |
0.04 |
Insulation Resistance (20 ¡æ): PVC insulation not less than 25M¦¸.Km; FEP or PEA insulation not less than 100M¦¸.Km¡£
Flame retardant properties: The class A (at GB12666.5-90 test)
Specifications :
Structure \ section mm2 |
0.2 |
0.5 |
1.0 |
1.5 |
2.5 |
On the number of cores |
Single strand wire coremm |
1/0.52 |
1/0.80 |
1/1.13 |
1/1.37 |
1/1.76 |
Wire 1 on
Cable 2-37 pairs |
Multi-strand wire coremm |
7/0.20 |
7/0.30 |
7/0.43 |
7/0.52 |
19/0.41 |
Delivery requirements
And compensation for thermocouple compensation wire cable delivery length is not less than 100 meters, allowing the length of not less than 20 meters off a short delivery, and their number should not exceed 10% of the length of delivery
According to the agreement to allow any length of cable delivery |