ÖÐÎÄ°æ English
          Home©¦  Company©¦  Product©¦  Quality©¦  Sales©¦  Contact
 
 Flow meter series
 Transmitter meter...
 Pressure Meter Series
 Temperature meter...
 Check meter series
 Display Instrument...
 Wire and cable series
 Electric heating series
 
  The working principle of...
  Zirconia Oxygen Sensor...
  Hazardous gas detection...
  Our instrument for...
  China Hi-tech instrumentation.
  Development of Xi'an ...
  Precision temperature...
  The development trend of ...
  Description of several gas...
  Use of sensor technology...
  New sensors monitor the...
 
  Jiangsu Golden Delicious Control Technology Co., Ltd.,
  TEL£º0517-86867887
     0517-86867888
     0517-86867889
  FAX£º0517-86891587
Join Hotline£º0517-86803168
              13905232000
  Technical Support£º0517-86886468
  Zip:211600
  Address:Jiangsu Province, Lake County gongyuan Road, No. 1
 You are Here > Home > Product
     

JGLWGY Turbine flowmeter

 

JGLWGY Turbine flowmeter

The SKLWGY turbine wheel flow sensor is one kind of precise flow measurement measuring appliance, necessary may use in with the corresponding current capacity integration measuring appliance surveying the liquid the current capacity and the total quantity. Widely uses in domain and so on petroleum, chemical industry, metallurgy, scientific research measurements, the control system. The equipment has the turbine wheel flow sensor which the health attaches to be possible to apply in the drugs manufacture profession.

The integration turbine meter structure is the explosion-proof design, may demonstrate the current capacity total quantity, transient flow and the current capacity fullness percentage. The battery uses the persistent effect lithium battery, the single function integration table battery service life may amount to above 5 years, the multi-purpose display battery service life may also achieve above 12 months.

The integrated meter may demonstrate the Flux unit is numerous, has the cubic meter, the gallon, rises, the standard cubic meter, the standard rises and so on, may establish the fixed pressure, the temperature parameter to carry on the compensation to the gas, to the pressure and the temperature parameter variation not big situation, may use this measuring appliance to carry on the fixed compensation integration.

Liquid turbine meter's technical performance

Regarding the viscosity high hydraulic fluid, the machine oil, the small caliber specification may use the solid class demarcation.

Nominal size DN

Current capacity scope m3/h

Fluid temperature ¡æ

Nominal pressure PN

(Mpa)

Ambient temperature ¡æ

Relative humidity %

Most tremendous pressure loss MPa

Intrinsic error

¡À0.2%

Intrinsic error

¡À0.5%

Intrinsic error

¡À1.0%

Lower limit

Upper limit

Lower limit

Upper limit

Lower limit

Upper limit

2A

?

?

?

?

0.01

0.13

?

?

?

?

?

-20~+120

6.3 16 25 40

?

?

?

?

?

-25~+55

?

?

?

?

?

¡Ü80

0.15

4A

?

?

?

?

0.04

0.25

0.12

6A

?

?

0.1

0.6

0.1

0.6

0.08

10A

?

?

0.25

1.2

0.2

1.2

0.05

15A

1.2

5

0.6

4

0.5

5

0.035

25A

2

10

1.6

10

1

10

40A

?

?

3

20

2

20

2.5

?

?

?

?

?

?

0.025

40B

4

20

3

20

2.5

25

50A

?

?

6

40

4

40

50B

8

40

4

40

4

40

80A

?

?

16

100

10

100

80B

20

100

10

100

16

160

100A

?

?

25

160

20

200

1.6 or 2.5

100B

25

160

20

160

20

200

150A

?

?

50

300

40

400

150B

50

300

40

300

40

400

200A

120

600

100

600

80

800

250A

200

1000

160

1000

120

1200

1.6

300A

?

?

250

1600

180

1800

SKLWGY turbine wheel flow sensor's model and specification code number table

Model

Specification code number

Explanation

SKLW

Turbine wheel flow instrument

?

G

Sensor

?

Q

Gas

?

Y

Liquid

?

Nominal size

-2

2mm (pipe thread G3/8 ")

-4

4mm (pipe thread G1/2 ")

-6

6mm (pipe thread G1/2 ")

-10

10mm (pipe thread G1/2 ")

-15

15mm (pipe thread G1 ")

-25

25mm (pipe thread G11/4 ")

-40

40mm (flange)

-50

50mm (flange)

-80

80mm (flange)

-100

100mm (flange)

-150

150mm (flange)

-200

200mm (flange or jack-in type)

-250

250mm (flange or jack-in type)

-300

300mm (flange or jack-in type)

?

Precision class

A

Precision 1%

B

Precision 0.5%

C

Precision 0.2%

?

Signal output

M

The integration liquid crystal display and has the 4~20mA electric current output

J

Necessary current capacity integrating meter fission demonstration

S

The necessary current capacity integrating meter fission demonstrates and outputs 4~20mA

I

4~20mA electric current output

T

Integration liquid crystal display

P

Pulse output

?

Nominal pressure

C1

PN1.6MPa

C2

PN2.5MPa

C3

PN4.0MPa

C4

PN6.3MPa

C5

PN16MPa

C6

PN25MPa

C7

PN40MPa

Explosion-proof request

/NE

Does not guard against explosions

/EX

Explosion-proof rank d¢òBT4

Temperature request

/NE

Normal temperature

/HE

120¡æ¡Ý high temperature ¡Ý150¡æ


Switch engineering data

Power source

Exchange

85-265V,45-400Hz

Cocurrent

11-40V

Operates the key and the demonstration

Presses a key the type

4 thin film pressed keys may establish choose the complete parameter, may also use the PC machine (RS232) pair of switch hypothesis programming;

3 line of LCD wide angles of view, the width are warm, belt back light demonstration;

1st line of demonstration flow rate;

2nd line of demonstration Flux unit;

3rd line of demonstration current capacity percentage, to total quantity, reverse total quantity, differential value total quantity, warning, speed of flow.

Magnetism key type

2 magnetism keys use in demonstrating that the parameter the choice and the replacement, use the PC machine (RS232) pair of switch hypothesis programming;

2 line of LCD wide angles of view, the width are warm, the belt back light demonstrated:

The 1st line: Magnetism key choice: Demonstrates the current capacity percentage, to the total quantity, the reverse total quantity, the differential value total quantity, the warning, the speed of flow.

The 2nd line: Demonstrates the current capacity.

Internal integrator

Forward total quantity, reverse total quantity and differential value total quantity.

Output signal

Unidirectional analog output

Entire isolation, load ¡Ü600D. (when 20mA);

Upper limit: 0-21mA may elect, each grade of lmA;

Lower limit: 0-21mA may elect, each grade of 1mA;

Forward and reverse current capacity output mode programming.

Bidirectional analog output

The lower limit limit is. Or 4mA, other with unidirectional analog output.

Double-sided pulse output

Two group output distinction correspondence forward and the reverse current capacity, frequency 0~800Hz, upper limit 1-800Hz may elect, each grade of IHz;

Square-wave or designation pulse width, designation pulse width upper limit 2.5S, each grade of 1ms;

The passive isolation transistor switched output, may absorb 250mA the electric current, pressure resistance 35V.

Two-circuit warning output

May report to the police (programming) the high/low current capacity, the blank pipe, the malfunction, positive, the reverse current capacity, the simulation quantity ultra measuring range, the pulse quantity ultra measuring range, the pulse small signal excision, the output polarity may elect;

The belt isolation protection's transistor switched output, may absorb 250mA the electric current, pressure resistance 35V. (and pulse output isolation)

Digital communication

¡¡

RS232, RS485, HART


Lining's choice

Lining material

Main performance

Highest medium temperature

Applicable scope

- build

Separation

¡¡

Teflon (F4)

Is the chemical properties stablest one kind of plastic, the ability ebullition hydrochloric acid, the sulfuric acid, the nitric acid and the aqua regia, also ability thick alkali and each organic solvent. Does not bear the boron trifluoride chlorine, the high temperature boron trifluoride chlorine, the high flow rate liquid fluorine, the liquid oxygen, from the oxygen corrosion.

70¡æ

100¡æ 150¡æ (needs special orders)

1st, concentrated acid, alkali and so on strong corrosive medium. 2nd, health class medium.

Gathers the entire fluorine second grade propylene (F46)

With F4, the resistance to wear, anti-negative pressure ability are higher than F4.

With on

¡¡

Gathers the fluorine to gather the ethylene (Fs)

Is suitable the temperature upper limit to compare the teflon to be low, but the cost is also low.

80¡æ

¡¡

Gathers the chloroprene rubber

1st, has the extremely good elasticity, the altitude breaking tenacity, the wear-resisting performance is good. 2nd, bears the general low concentration acid, the alkali, the salty medium corrosion, does not bear the oxidized medium the corrosion.

80¡æ 120¡æ (needs special orders)

Water, sewage, weak wearability mud pulp.

Polyurethane rubber

1st, the wear-resisting performance is greatly strengthened.

2nd, the anti-corrosive performance is bad.

80¡æ

Neutral strong attrition pulp, coal tar, mud


Import protection flange and earth flange (or earth link) choice

Flange type

Applicable scope

Earth flange (or earth link)

Is suitable in the non-conductor pipeline, if plastic pipeline, but has earth electrode's sensor not to need.

Import protection flange

When the medium has the strong wearability selects.


Electrode's choice

Electrode material

Anticorrosion and wear-resisting performance

Stainless steel 0Crl8Nil2M02Ti

Uses in the process water, the domestic water, the sewage and so on having the pickling medium, is suitable in Industry sectors and so on petroleum, chemical industry, steel and iron and, domains and so on municipal administration, environmental protection.

Alloy B

Has the good corrosion resistance to below the boiling point all density's hydrochloric acid, also bears the sulfuric acid, the phosphoric acid, the hydrofluoric acid, the organic acid and so on non-chlorination acid, the alkali, non-oxidized salty fluid corrosion.

Alloy C

Ability non-oxidized acid, like nitric acid, nitration mixture, or chromic acid and sulfuric acid mix medium corrosion, also bears the oxidized salt as for example: Fe,¡±, Cu¡± under or including other oxidant's corrosion, like is higher than the normal temperature the hypochlorous acid salt brine, the sea water corrosion

Titanium

Ability sea water, each kind of chloride and hypochlorite, oxidized acid (including fuming sulfuric acid), organic acid, alkali corrosion. Does not bear the pure reducible acid (for example sulfuric acid, hydrochloric acid) corrosion, but like in the acid includes the oxidant (for example nitric acid, Fc++, Cu++) time, then corrodes to reduce greatly.

Tantalum

Has the fine corrosion resistance and the glass is very similar. Besides the hydrofluoric acid, the fuming sulfuric acid, the alkali, the ability - - cuts the chemical mediator nearly (including boiling point hydrochloric acid, nitric acid and the l 50¡æ following sulfuric acid) the corrosion. In alkali tricky; Anticorrosion.

Platinum/titanium alloy

The ability - - cuts the chemical mediator nearly, but is not suitable for the aqua regia and the ammonium salt.

Stainless steel spreading tungsten carbide

Uses in non-corrosiveness, strong wearability medium.

Note: As a result of the medium great variety, its corrosiveness receives the temperature, the density, the speed of flow and so on complex factor influence to change, therefore this table only supplies the reference. The user should act according to actual situation make the choice, when the necessity should do plans to choose the material the anticorrosive experiment, like lacing film experiment.


SKLD series electromagnetic flowmeter measuring appliance shaping
¡ô measuring range scope confirmation
Generally the industrial used electromagnetic flowmeter was measured that the medium speed of flow take 2~4m/s as suitable, in the peculiar circumstance, the lowest speed of flow should not be smaller than 0.2m/s, highest should not be bigger than 8m/s. If in the medium includes the solid particle, the commonly used speed of flow should be smaller than 3m/s, prevents the lining and electrode's excessive friction; Regarding the viscous fluid, the speed of flow may choose is bigger than 2m/s, the great speed of flow is helpful to eliminates sluggish which automatically on the electrode adheres to stick cohere the function, is advantageous in the enhancement measuring accuracy.
In measuring range Q had determined under the condition, then acts according to above speed of flow V scope decision flowmeter caliber D the size, its value calculates based on the equation below:
Q=¦ÐD2V/4
Q: Current capacity (©O/h) D: Pipeline inside diameter V: Speed of flow (m/h)
Electromagnetic flowmeter's measuring range Q should be bigger than the estimate the maximal-flow size, but the normal flow rate take is bigger than the flowmeter full scale scale division suitably slightly 50 as.
¡ôSKLD series electromagnetic flowmeter reference current capacity scope

Caliber mm

Current capacity scope m3/h

Caliber mm

Current capacity scope m3/h

¦Õ15

0.06~6.36

¦Õ450

57.23~5722.65

¦Õ20

0.11~11.3

¦Õ500

70.65~7065.00

¦Õ25

0.18~17.66

¦Õ600

101.74~10173.6

¦Õ40

0.45~45.22

¦Õ700

138.47~13847.4

¦Õ50

0.71~70.65

¦Õ800

180.86~18086.4

¦Õ65

1.19~119.4

¦Õ900

228.91~22890.6

¦Õ80

1.81~180.86

¦Õ1000

406.94~40694.4

¦Õ100

2.83~282.60

¦Õ1200

553.90~55389.6

¦Õ150

6.36~635.85

¦Õ1600

723.46~72345.6

¦Õ200

11.3~1130.4

¦Õ1800

915.62~91562.4

¦Õ250

17.66~176.25.

¦Õ2000

1130.4~113040.00

¦Õ300

25.43~2543.40

¦Õ2200

1367.78~136778.4

¦Õ350

34.62~3461.85

¦Õ2400

1627.78~162777.6

¦Õ400

45.22~4521.6

¦Õ2600

1910.38~191037.6

The SKLDE series intelligence electromagnetic flowmeter chooses the spectrum

Model

Caliber

?

SKLD

15~2600

?

?

Code number

Installs the form

?

Y

Integration

F

Fission type

?

Code number

Switch model

ZA

Circular

ZB

Square shape

?

Code number

Output signal

I.4

4~20mA

f

Frequency 1KHz

Rs

Serial communication (485)

C

Control output

?

?Code number

Explosion-proof request

?N

Does not have the explosion-proof

EX

The explosion-proof (is only suitable for fission type)

?

Code number

Medium temperature

T1

¡Ü65¡æ

T2

¡Ü65¡æ

T3

¡Ü180¡æ (is only suitable for fission type)

?

Code number

Inside lining material quality

NE

Chloroprene rubber (¡Ü65¡æ)

PTFE

Teflon (¡Ü189¡æ)

PVC

Polyvinyl-chloride (¡Ü70¡æ)

?

Code number

Electrode material quality

316L

Stainless steel

HC

Alloy C

HB

Alloy B

Ti

Titanium

Ta

Tantalum

The serial products includes: The integration electromagnetic flowmeter, the fission type electromagnetic flowmeter, the jack-in type electromagnetic flowmeter, the anti-corrosive electromagnetic flowmeter, brings the communication electromagnetic flowmeter

All rights reserved£ºJiangsu Golden Delicious Control Technology Co., Ltd.,        Tel:0517-86867887 0517-86803168     Tex:0517-86891587
Temperature Instrumentation Division     Pressure Instrumentation Division         Calibration instruments Division
Flow meter Division     Display Instrument Division     Instrument Division transmitter      Wire and Cable Business Unit