Characteristic
|
??? The JG-YBS-WY pressure verification meter the installment has the suppression hand-pump for the AC-DC, causes it to become the ideal scene check meter. |
The pressure verification meter high performance's microprocessor and the linearity carries on the continuous modification to measuring appliance zero, guaranteed that in the measuring appliance long time zero and the accuracy has the good duplication and the stability, the survey accuracy is high. |
The pressure verification instrument has the ultra measuring range warning function, when the applied pressure surpasses the fixed full scale +2500 word-time, the measuring appliance will demonstrate OVER RANGE! And P the built-in buzzer will emit off and on sound, expressed that the pressure (electric current) surpasses the full scale, should stop the compression, and downloads the partial pressures to cause it to stipulate in the measuring range, in order to avoid damage pressure transmitter. |
When the pressure verification meter surveys the electric current surpasses when 22mA the measuring appliance will demonstrate OVER RANGE! I and the built-in buzzer will emit off and on sound, expressed that measures the electric current ultra measuring range. |
Pressure verification meter software full of meat, simplicity of operator, perspicuity. |
Uses the thin film kneading board and enters touches the opening lightly seasoned, the up-to-date styling, presses a key the life to be long. |
?LCD back light, pressure, electric current demonstration, direct-viewing, clear, structure compact reasonable. The intelligent pressure verification meter volume is small, the weight light, carries conveniently. |
The intelligent pressure verification meter front panel installs the hand to hold the pressure generator, - 90KPa~1.6MPa, and has the trimming, to put the valve. The manual vacuum rate reaches 95%, has the world advanced level. The pressure source spare part is good after the fine attrition gas tightness, conforms to the IP54 seal standard. |
May operate directly on the kneading board, correction full scale. |
The metal shell, anti-jamming, bears the ramming reliably. |
The volume declines the accent, extremely easy to realize an examination pressure. |
* technical specification |
Pressure measuring range: - 95KPa~1.6MPa |
Resolution: Pressure: Min 1Pa |
Electric current: Min 1uA |
Current measurement scope: 0~22mA |
Direct-current output: 24VDC |
Accuracy: Pressure: 0.1%F ¡¤ S 0.05%F |
Electric current: 0.05%¡À1d |
Relative humidity: ¡Ü80%RH |
Overload capacity: For measuring range upper limit 1.2~1.5 times |
External dimensions: 240¡Á80¡Á40mm |
Weight: 2.5Kg |
Built-in battery: A charge may work for 15 hours |
* shaping table |
Measuring range |
Measuring range |
Resolution |
Negative pressure |
Precision |
Precision |
Stability
(one year) |
Hand-pump |
JG-YBS-WY |
10KPa |
1Pa |
- |
0.10% |
0.075% |
¡À0.1%F ¡¤ S |
Built-in |
JG-YBS-WY |
16KPa |
1Pa |
- |
0.10% |
0.075% |
¡À0.1%F ¡¤ S |
Built-in |
JG-YBS-WY |
20KPa |
1Pa |
- |
0.10% |
0.075% |
¡À0.1%F ¡¤ S |
Built-in |
JG-YBS-WY |
25KPa |
1Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
40KPa |
1Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
60KPa |
1Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
100KPa |
10Pa |
- |
0.10% |
0.075% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
160KPa |
10Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
200KPa |
10Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
240KPa |
10Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
100KPa |
10Pa |
-95KPa |
0.10% |
0.075% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
160KPa |
10Pa |
-95KPa |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
200KPa |
10Pa |
-95KPa |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
240KPa |
10Pa |
-95KPa |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
0.4MPa |
10Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
0.6MPa |
10Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
1MPa |
100Pa |
- |
0.10% |
0.075% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
1.6MPa |
100Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
2.0MPa |
100Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
2.5MPa |
100Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
4.0MPa |
100Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
6.0MPa |
100Pa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
10.0MPa |
1KPa |
- |
0.10% |
0.075% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
16.0MPa |
1KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Built-in |
JG-YBS-WY |
20MPa |
1KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
JG-YBS-WY |
25MPa |
1KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
JG-YBS-WY |
40MPa |
1KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
JG-YBS-WY |
60MPa |
1KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
JG-YBS-WY |
100MPa |
10KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
JG-YBS-WY |
160MPa |
10KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
JG-YBS-WY |
200MPa |
10KPa |
- |
0.10% |
0.05% |
¡À0.075%F ¡¤ S |
Outside sets |
|