ÖÐÎÄ°æ English
          Home©¦  Company©¦  Product©¦  Quality©¦  Sales©¦  Contact
 
 Flow meter series
 Transmitter meter...
 Pressure Meter Series
 Temperature meter...
 Check meter series
 Display Instrument...
 Wire and cable series
 Electric heating series
 
  The working principle of...
  Zirconia Oxygen Sensor...
  Hazardous gas detection...
  Our instrument for...
  China Hi-tech instrumentation.
  Development of Xi'an ...
  Precision temperature...
  The development trend of ...
  Description of several gas...
  Use of sensor technology...
  New sensors monitor the...
 
  Jiangsu Golden Delicious Control Technology Co., Ltd.,
  TEL£º0517-86867887
     0517-86867888
     0517-86867889
  FAX£º0517-86891587
Join Hotline£º0517-86803168
              13905232000
  Technical Support£º0517-86886468
  Zip:211600
  Address:Jiangsu Province, Lake County gongyuan Road, No. 1
 You are Here > Home > Product
     

JG-WZJ-T Thermocouple, RTD automatic calibration device

JG-WZJ-T-type thermal automatic verification system is the latest developed the fourth generation of automatic verification of thermal products. It is in the Windows environment, the full use of the language under Windows environment, develop a new generation of products, systems based on high-end microprocessor as the core, together with imports of high-precision digital multimeter, and low potential scan switch, power regulator and other form of monitoring and control System. Operator in the Chinese Win95 / Win98 / WinMe operating system easily with the mouse the whole process of operation, computer systems real-time display test furnace (or tank, etc.) temperature curve, parameters such as temperature and test time. System is fully in accordance with national verification procedures for data processing, and can print a variety of record forms, test certificate, can retain the original records for future reference. System is fully implemented thermocouple and thermal resistance of the full automation of the certification process, namely: automatic temperature control, automatic test, automatic data processing, automatic print test results. Allow the operator to greatly reduce the labor intensity and improve the quality of the work test. The device also provides the system's certification program and data file management procedures, operator certification and verification of the results of the system archiving, retrieval and search more convenient.

Specifications

Potential scan switches parasitic ¡Ü0.4 u V
Resolution Measurement of the maximum potential resolution 0.1 u V
The highest resolution resistance measurement 0.1m ¦¸
Accuracy Resistance Measurement Uncertainty ¡Ü0.01%
Resistance Measurement Uncertainty ¡Ü0.01%
Uncertainty of thermocouple test ¡Ü1.2¡æ
£¨Second annual change with standard thermocouple 0.7¡æ)
Uncertainty of heat resistance test ¡Ü0.05¡æ
The stability of temperature After the certification process temperature thermocouple temperature changes ¡Ü0.2¡æ/min
After the verification process of thermal resistance constant temperature tank ¡Ü0.04¡æ/min
Automatic cold junction compensation When the cold junction temperature (20 ¡À 10) ¡æ range, the compensation error ¡Ü0.2¡æ
Test temperature Thermocouple 300¡«1100¡æ
Thermal resistance 0 ~ 300 ¡æ (including temperature thermocouple)
Test count Thermocouple can be supported simultaneously test 1-5
Thermocouple can be supported simultaneously test 1-5 £¬Thermal resistance at the same temperature point to allow multi-batch testing
Point of a continuous test Thermocouple 4
Thermocouple3¸ö
Test time Thermocouple test, under normal conditions, about 30 minutes per Baidu
Work environment Ambient temperature 20¡æ¡À3¡æ
Relative Humidity ¡Ü75%
Use the power AC220V¡À10% 50¡À1HZ
Require grounding resistance ¡Ü4¦¸

System hardware configuration

JG-WZJ-T thermal automatic verification system consists of high-precision digital multimeter, master box, SCR controller, computer system, the thermostat (test furnace and tank) and measure the composition of wire and communications cable, as shown .


JG-WZJ-T thermal instrumentation, automatic check system configuration list

Computer System Name Units Quantity Remarks
Host Sets 1 Configuration P4 2.0 or above 256M 60G, optical floppy drive, control board (assembled)
Monitor Taiwan 1 17-inch flat screen
Laser Printers Taiwan 1 EPSON or CANON Series
Computer desk Zhang 1
Communication cable Root 1
Multi-outlet 2.peace 2
Data Acquisition System Master Box 2.peace 1
Measurement and control cables Sets 1
Multimeter (import) Root 1 KEITHLEY 6 1 / 2 bit (import)
Temperature Sensor Support 1 With cold junction compensation
Temperature control system SCR regulators Taiwan 1
Control signal Root 1
Power Line Root 1
Other accessories Test tube furnace Taiwan 1
Standard tank Taiwan 1
Standard tank Taiwan 1
Freezing device Taiwan 1
Ice record Taiwan 1
Second-class standard of thermal resistance Support 1
Second-class standard thermocouple Support 1
Second standard pipe thermometer work Sets 1
Software Information Sets 1 Software CD-ROM, certificate, statement



All rights reserved£ºJiangsu Golden Delicious Control Technology Co., Ltd.,        Tel:0517-86867887 0517-86803168     Tex:0517-86891587
Temperature Instrumentation Division     Pressure Instrumentation Division         Calibration instruments Division
Flow meter Division     Display Instrument Division     Instrument Division transmitter      Wire and Cable Business Unit